Non-Destructive Testing

Inspection without an acceptance criterion produces findings, not decisions

Method selection by defect location: surface, near-surface and volumetric methods

Non-destructive testing is the collective name for the methods that find discontinuities in and on a component without taking it out of service. Inspection alone, however, produces no result: whether a discontinuity counts as a defect is decided by an acceptance criterion agreed beforehand. And the method is chosen by the defect itself — where it sits, what type it is and which way it faces.

What this note covers

Inspection Is a Decision Tool

Non-destructive testing does not make a part good; it tells you whether the part is acceptable against a stated criterion. Every method has a different sensitivity, a different orientation preference and a different blind spot, so the question is never “shall we inspect?” but “which defect, at which location, of which size, must be found — and which method can actually find it?”

The most common mistake: treating a clean report as proof that the part is defect free. It only means that no indication above the detection threshold of that method, in that orientation, was found by that operator.

The Logic of Method Selection: Location and Orientation

Two questions settle most choices. Is the defect at the surface or in the volume? Surface and near-surface flaws are found by visual, penetrant, magnetic particle and eddy current testing; internal flaws need ultrasonic or radiographic testing. How is the defect oriented? Radiography sees volumetric defects (porosity, slag) well and can completely miss a tight planar crack lying across the beam; ultrasonic testing is the opposite — excellent on planar defects aligned to reflect the beam, less informative on scattered porosity. Lack of fusion in a weld is a planar defect: it is a UT problem, not an RT problem.

Surface Methods

Visual testing (ISO 17637) is the cheapest and most underrated method. With adequate light, access, a gauge and a trained eye it finds undercut, misalignment, profile errors and gross cracking — and it is a prerequisite for everything that follows.

Penetrant testing (ISO 3452) draws a coloured or fluorescent liquid into surface-breaking discontinuities by capillary action. It works on any non-porous material, including austenitic stainless and aluminium, but only on defects open to the surface and only on a clean surface — blasting or machining can smear a crack closed and hide it.

Magnetic particle testing (ISO 17638 / ISO 9934) magnetises a ferromagnetic part and reveals flux leakage at surface and slightly subsurface defects. It is faster and more sensitive than PT, and it works through thin coatings.

Two vital rules for MT: the magnetic field must run across the expected crack, so each area is examined in two perpendicular directions; and the part must be demagnetised afterwards if it will be machined, welded or run in a bearing.

Eddy current testing (ISO 15549) induces currents in conductive material and senses the disturbance. It is fast, non-contact and well suited to tube inspection, surface cracks and sorting of material or heat treatment condition — but it is sensitive to geometry, lift-off and conductivity, so it needs careful calibration on representative standards.

Volumetric Methods

Ultrasonic testing (ISO 16810; welds ISO 17640) sends a high-frequency pulse into the material and times the echoes. It gives depth information, needs access from only one side, and detects planar defects superbly. It depends heavily on operator skill, surface condition and couplant, and it struggles with coarse-grained materials such as austenitic welds and castings. Phased array and time-of-flight diffraction (TOFD) add imaging and reliable sizing — and, importantly, a permanent record.

Radiographic testing (ISO 17636) images density differences through the section. It produces an intuitive, archivable record that non-specialists can read, and it is the traditional choice for castings and for weld porosity and inclusions. The costs are radiation safety, exclusion zones, exposure time, and insensitivity to tight planar flaws.

Comparison

MethodFindsMisses / limitsNotes
VTSurface geometry, visible cracks, profileAnything not visibleCheapest; always first
PTSurface-breaking cracks, any non-porous materialSubsurface defects; needs clean, open surfacesConsumables, cleaning, waste
MTSurface and near-surface cracksNon-ferromagnetic materialsTwo field directions; demagnetise after
ETSurface cracks, tubes, sortingDepth limited; geometry sensitiveFast, automatable
UTInternal planar defects, thickness, depthCoarse grain, complex geometry, near-surface dead zoneOperator dependent; phased array gives records
RTVolumetric defects, an archivable imageTight planar cracks, thick sectionsRadiation protection governs planning

What “Clean” Means: Probability of Detection

Detection is statistical, not binary. A POD curve describes the probability of finding a defect as a function of its size for a given method, procedure and inspector. Engineering uses it honestly by designing around the size that can be found: the damage tolerance approach assumes an undetected crack just below the detection threshold and sets the inspection interval so that it cannot grow to critical size before the next inspection. That is the bridge between NDT and fracture mechanics.

People, Procedures and Acceptance

  • Qualification of personnel: EN ISO 9712 levels 1–3 — the method is only as good as the operator, and level 3 writes the procedures.
  • Written procedure: technique, equipment, calibration blocks, scanning plan, sensitivity setting and acceptance criteria, agreed before the work starts.
  • Acceptance levels: for welds, EN ISO 5817 quality levels B / C / D, chosen for the application; the same indication can be acceptable in one joint and rejectable in another.
What a report must contain: what was inspected, to which procedure and standard, with which equipment and calibration, what was found with position and size, and the acceptance criterion applied. A report that only says “OK” cannot be used in any later investigation.

The technical note below (A4 PDF, in Turkish) develops these subjects in depth with original diagrams prepared for this series.